menu "Iris Thread Manager"
    depends on IDF_TARGET_ESP32C6 || IDF_TARGET_ESP32H2

    config IRIS_ENABLED
        bool "Enable Iris Thread device management"
        default y
        depends on OPENTHREAD_ENABLED
        help
            Enables the Thread Border Router, Commissioner, and device management.
            Requires ESP32-C6 or ESP32-H2 target with OpenThread support.

    config IRIS_MAX_DEVICES
        int "Maximum number of paired Thread devices"
        default 32
        range 1 64
        depends on IRIS_ENABLED
        help
            Maximum number of paired H2 devices stored in SPIFFS and kept in memory.

    config IRIS_INVENTORY_INTERVAL_MS
        int "Inventory poll interval (ms)"
        default 30000
        range 5000 300000
        depends on IRIS_ENABLED
        help
            How often the inventory task polls all paired devices for their current state.

    config IRIS_OFFLINE_THRESHOLD
        int "Failed polls before marking device offline"
        default 3
        range 1 10
        depends on IRIS_ENABLED
        help
            Number of consecutive CoAP timeout/errors before a device is marked offline.

    config IRIS_DISCOVERY_WINDOW_MS
        int "Discovery response collection window (ms)"
        default 3000
        range 500 10000
        depends on IRIS_ENABLED
        help
            How long the C6 waits for responses after sending a multicast GET /discover.
            Longer values catch slow or distant devices; shorter values speed up boot.

    config IRIS_DISCOVERY_INTERVAL_CYCLES
        int "Re-discovery every N inventory cycles"
        default 10
        range 1 100
        depends on IRIS_ENABLED
        help
            A full discovery sweep (multicast GET /discover) is run automatically
            every N inventory poll cycles. At the default of 10 cycles × 30 s = 5 min.
            Set to 1 to rediscover every cycle (more network traffic).

    config IRIS_JOINER_PSKD
        string "Thread Joiner PSKd (Pre-Shared Key)"
        default "JOINPW01"
        depends on IRIS_ENABLED
        help
            The Pre-Shared Key for Device used during Thread commissioning.
            Must match the PSKd compiled into the H2 firmware.
            Minimum 6 characters, maximum 32 characters.

    config IRIS_MASTER_PRIORITY
        int "Master election priority (higher = preferred Master)"
        default 1
        range 1 255
        depends on IRIS_ENABLED
        help
            Priority used in Master/Backup election. The device with the highest
            priority becomes Master. Configure the primary C6 with a higher value
            (e.g., 2) than the backup (e.g., 1).

    config IRIS_MASTER_HEARTBEAT_INTERVAL_MS
        int "Master heartbeat broadcast interval (ms)"
        default 5000
        range 1000 30000
        depends on IRIS_ENABLED
        help
            How often the active Master broadcasts a heartbeat to the Thread multicast
            group ff03::1 so the Backup knows the Master is alive.

    config IRIS_MASTER_FAILOVER_TIMEOUT_MS
        int "Failover timeout — max time without a heartbeat (ms)"
        default 15000
        range 3000 60000
        depends on IRIS_ENABLED
        help
            If the Backup receives no heartbeat from the Master within this timeout,
            it starts a new Master election. Should be > 3 × HEARTBEAT_INTERVAL.

endmenu